Alto-Shaam ASF-60G Fryer User Manual


 
MN-35207 • Gas Fryer Operation & Care Manual • 10
INSTALLATIONINSTALLATION
An electrical wiring diagram is located in the fryer kettle.
Thefryermustbeinstalledbyaqualiedelectrician.This
appliance must be branch circuit protected with proper
ampacities, in accordance with the wiring diagram. The
fryer must be properly grounded in accordance with the
National Electrical Code and applicable local codes. A
means to disconnect the unit must be incorporated into the
xedwiringinaccordancewithwiringcodes.
Wiresizeforthemainincomingpowertotheunitmust
matchtheminimumsizelistedinthespecications
applicabletothespecicfryer.
Before operating the fryer, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
ELECTRICAL REQUIREMENTS
Hard wired models:
Hard wired models must be equipped with a
countrycertifiedexternalallpoledisconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
productanoilresistantcordlikeH05RNorH07RN
or equivalent must be used.
 To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS KW CORD & PLUG
120 1 60 2.2 0.27
230 1 50 1.0 0.23
NEM A
5-15P
15A-125V PLUG
CEE 7/7
220-230V PLUG