MN-35207 • Gas Fryer Operation & Care Manual • 7
INSTALLATIONINSTALLATION
35.15
I
2H(20),
I
2E(20),
I
2E+(20/25),
I
2L(25),
I
3+(28-30/37),
I
3B/P(30),
I
3B/P(37),
I
3B/P(50),
I
3P(37),
I
3P(50)
17.5(NAT)and27.5(LP)
12.5 (NAT) and 25 (LP)
Infrared type with blower and venturi valve
1
N/A
N/A
Variable pre-set at factory
Direct spark electronic ignition
20.995mmmalethread
The Alto-Shaam open gas fryer has been set to operate
with either natural gas or propane as indicated on the
fryer identification name plate.
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressuretestingofthatsystemattestpressuresinexcessof1/2
psi. The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi.
NOTE:
GAS PRESSURE CHART
The fryer has been factory adjusted according to
the gas type specified on the fryer identification
name plate.
GAS FRYER TECHNICAL SPECIFICATIONS
Natural Gas
Min.ConnectedPressure 5.0"W.C. 1.2kPa
Max.ConnectedPressure 11.0"W.C. 2.74kPa
Gas Consumption 120 CFM
Gross Thermal Output 120,000 Btu/hr
Propane Gas
Min.ConnectedPressure 10.0"W.C. 2.5kPa
Max.ConnectedPressure 14.0"W.C. 3.5kPa
GasConsumption 48CFM
Gross Thermal Output 120,000 Btu/hr
GAS SPECIFICATIONS
DANGER
CONNECTING TO THE WRONG GAS
SUPPLY COULD RESULT IN FIRE OR
AN EXPLOSION CAUSING SEVERE
INJURY AND PROPERTY DAMAGE.
WARNING
TO AVOID SERIOUS PERSONAL
INJURY, installation of this appliance
must conform to local, state, and
national codes; the current edition
of the American National Standard
Z223.1, National Fuel Gas Code, and
all local municipal building codes.
In Canada, installation must be in
accordance with Standard CAN/CSA
B 149.1 and Installation Codes - Gas
Burning Appliances, and local codes.
I
2H
at 20 mbar for use in AT, DK, FI, IE, IT, PT, SE, CH.
I
2E(20)
at 20/25 mbar for use in DE, LU.
I
2E+(20/25)
at 20/25 mbar for use in BE, FR.
I
2L(25)
at 25 mbar for use in NL.
I
3+(28-30/37)
at28-30/37mbarforuseinBE,FR,IE,IT,LU,PT,CH.
I
3B/P(30)
at 30 mbar for use in DK, FI, NL, SE.
I
3B/P(50)
at 50 mbar for use in AT, DE, CH.
I
3P(37)
at37mbarforuseinFI,DE,IE,CH.
INSTALLATION REQUIREMENTS
1/2"NPT
Check plumbing codes for proper supply line sizing to attain
minimum burner manifold pressure shown:
NATURAL GAS
5.0"W.C.
PROPANE GAS
10.0"W.C.
(1.2 kPa) (2.5 kPa)
MAX. RECOMMENDED
INLET PRESSURE:
11"W.C(2.74kPa) 14"W.C.(3.5kPa)
Ifaexiblegaslineisused,itmustbeAGA
approved, commercial type and at least 1/2" I.D.
Manual gas shut-off valve and restraining device must be installed
per code requirements when using a quick disconnect device.
NOT FACTORY SUPPLIED