Alto-Shaam CombiOven Oven User Manual


 
troubleshooting
CT EXPRESS STEP BY STEP OPERATION MANUAL • 53
ERROR CODES
Error
Code
Error Call Out in Display Description of Error Possible Cause
E27
N8 Immersion Element
Temperature Too High
Immersion element too hot Scale buildup inside steam generator and/or on water
level probe.
Immersion element contactor stuck closed.
Faulty N8 safety temperature probe.
E34
Steam Generator Drain
Pump Fault
Water level in steam
generator does not drop
during cleaning program
Scale buildup inside the steam generator and/or
water level probe.
Obstruction on inlet side of steam generator drain
pump.
Boiler steam generator pump not being energized.
Steam generator drain pump defective.
E36
Steam Temperature High Oven cavity temperature is
too high when operating in
steam mode or combination
mode
Water supply is not connected or shut off.
Low water pressure.
— Y1 solenoid valve not energized on a call for steam.
— Y1 solenoid faulty.
— Flow restrictor obstructed.
Water injection pipe obstructed.
Steam bypass hose obstructed.
B5 steam bypass probe dirty or faulty.
E51
No Water In Boiler Steam generator fi ll error Water supply is disconnected or shut off.
Low water pressure.
Boiler drain cap leaking or missing.
Boiler drain pump defective.
Drain pump elbow leaking.
Fill solenoid not energized.
Fill solenoid faulty.
Connection/wiring error at the solenoid or the
relay board.
Water level probe connection/wiring error at probe
or the relay board.
Water level probe requires descaling and/or
replacement.
E53
Fan Motor High
Temperature
Fan motor high limit Faulty motor high limit connection at relay board.
Obstructed fan wheel.
Faulty convection motor.
E54
Lower Fan Motor High
Temperature (20•20 unit
size only)
Fan motor high limit Faulty motor high limit connection at relay board.
Obstructed fan wheel.
Faulty convection motor.
E55
Vent Not Open Browning valve does not open Browning valve vent motor not being energized.
Alignment issue between motor cam and vent
motor safety switch (micro switch).
Faulty connection at vent motor, vent motor switch
or relay board.
Fault vent valve safety switch (micro switch).
Faulty vent motor.
(Continued on next page)