American Panel AP24BC250-3 Freezer User Manual


 
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual
28
F
INSTEAD OF AUTOMATIC you wish to select a MANUAL cycle, perform steps 1.a, 1.b, 1.c, 1.d,
1.e, 1f and 1.g (above), except in step 1.c press button
instead of button . The
in thoLED for "MANUAL" will then be steady "ON". The readouts se steps will be the same as
before.
NOTE: Cycle time can be changed only in Cycle Programming mode. To change the
programmed cycle time for any cycle see the instructions on Pages 17 to 25.
h. Press the
("START/STOP") button to start the cycle.
T
he display will show briefly:
hen the display will show:
with
01:29
T
alternating
W t ill coun
down
The MANUAL mode uses time and the air probe temperat
ill utomatically
ure to control the cycle.
The default total time for a soft cycle is 90 minutes. After the 90 minutes the unit w a
go into holding mode.
The display will show:
alternating with
00:00 Blinks
The operator can now end this cycle by pressing ("START/ STOP").
will show briefly: The display
STOPPING CYCLE . . .
STARTING CYCLE . . .
03.07.2006 10:41 AM
AIR 1 75°F
01:29
R / CHICKEN 140°F
Y / RO AST BEEF 143°F
B / CHICKEN 141°F
G / ROAST BEEF 142°F
03.07.2006 10:41 AM
AIR 1 34°F
00:00
R / CHICKEN 40°F
Y / ROAST BEEF 40°F
B / CHICKEN 40°F
G / ROAST BEEF 40°F
w: Then the display will sho
OPERATING MODE
OPERATING CYCLE
CHOOSE
. HARD CHILL CYCLE
3