Rotisserie/Convection Oven Operation
15
Edit the Basic Setup
1. Turn on the Main Power Switch. The Startup screen will briefly appear then the Controller Off screen will
display.
2. Touch anywhere on the touchscreen. The Recipe Selection screen will appear displaying a list of recipes.
3. Touch any recipe for 3 seconds. The Security screen will appear.
4. Use the up/down and left/right arrow buttons to enter the passcode and touch the GO button. The
Program Mode Selection screen will appear if a valid passcode is entered.
5. Touch the BASIC SETUP option. A Basic Setup Selection screen will appear.
6. Touch the parameter that needs to be changed. A Basic Setup Parameter Edit screen appears.
7. Change the parameter value using the left/right and up/down arrow buttons then touch the SAVE button
to save your changes. You will return to the Basic Setup Selection screen.
8. Repeat the process to change any other parameters.
9. Touch the X button as necessary to return to the Recipe Selection screen.
Programming the Controller Using the RS-232 Interface
The TouchTEC controller incorporates an RS-232 interface allowing factory and field personnel to read out,
modify and write in the entire recipe and controller configuration using a special Controller Configuration program
on a PC. The program allows a user to read the configuration data from the controller, edit any feature of the
configuration, write data back to the controller, save the data to a file on the PC and to retrieve the data from a
previously created file. The file saved in the PC contains a description field to aid in identifying the contents of the
configuration file. Follow the steps below to program the controller using the RS-232 interface.
1. Connect the communications interface module between the serial port on the PC and the controller.
2. Start the Controller Configuration program.
3. Select the COM port that the controller will use to communicate with the PC from the pull down list in the
Controller Com area.
4. Click the OPEN button and select a previously created configuration file or click the READ button to
download the configuration data from the controller.
5. Edit any of the following: Description of the configuration file, Recipe Parameters, Max number of recipes
visible, four digit passcode, Unit of Measurement for Temperature display and the Beep Type used at the
end of the cook cycle.
6. Touch the SAVE button and save the file using a different name.
7. Touch the WRITE button to upload the new configuration data back to the controller.
8. Disconnect the the communications interface module between the serial port on the PC and the
controller.