FITTING THE STABILITY BRACKET
It is recommended that if the appliance is to be installed with a flexible supply pipe and a stability bracket
(SK.4729.A) is fitted and is available from your supplier (see Important Safety Requirements, Page 42 ).
These instructions should be read in conjunction with the leaflet packed with the stability bracket.
1. Place the appliance in its intended position and level appliance.
2. Mark off 516 mm from the left hand side of the appliance as shown in Fig 4a. This is the centre line of
the fixing bracket.
3. Draw a line 100mm from the front edge of the levelling feet (see Fig.4a) and remove appliance from
its position. Mark off 438mm (see Fig.4a) back from this line on the centre line of the bracket to locate
the front edge of the lower bracket. Fix lower bracket (with two fixing holes) to the floor then measure
the height from floor level to engagement edge on back of appliance, dimension 'C' of Fig.4b.
4. Assemble upper bracket to lower bracket so that underside of bracket is dimension 'C' + 3mm above
floor level.
Reposition appliance and check that top bracket engages into appliance back as shown in Fig. 4b.
Fig.4a Fig.4b
INSTALLATION INSTRUCTIONS