Fisher & Paykel DD603M Dishwasher User Manual


 
March 2004 Manual 599082
- 21 -
Press Power to Exit at any time (All outputs will be switched off on exit).
As mentioned above the LCD display and touch switch panel LED’s are illuminated to correspond to a particular
hardware device. The following table details the display order of the test.
LCD Norm Fast Deli Rinse Hardware Output
-------------------------------------------------------------------------------------------
bL Off Off Off On Backlight
Er Off Off On Off Element Relay
Ld Off Off On On Lid Motors (will run for 10 seconds)
dd Off On Off Off Detergent Diverter Valve
FU Off On Off On Fill Water Valve
P1 Off On On Off Motor Wash direction
(2300-2850 rpm)
P2 Off On On On Motor Drain direction
(4200 rpm)
rd On Off Off Off Rinse Aid Dispenser (dispenses
current setting)
dF On Off Off On Drying fan
LE On Off On Off Rinse Aid LED
C1 On Off On On Water Softener Diverter Valve
C2 On On Off Off Water Softener Brine Pump
°C On On Off On Displays current water
temperature.
°E On On On Off Displays controller rail voltage
(C3 is used in the Factory to empty the Water Softener before the Product is packed.)
WARNING : In diagnostic mode there is no component protection. Therefore take care when running individual
components not to overload them. It is advisable to avoid turning the element on without filling the tub with water
first.
NB : No Fault codes will come up while in diagnostics mode.
Tub Home Sensor Test: At any time during HO test mode the Keylock symbol on the LCD display (Keylock LED
on integrated badge) indicates the tub position. On = Closed, Off = Open.
5.1.5 Fast Test Cycle
WARNING : only run this cycle if connected to the water supply
This level runs a 5 minute fast test cycle.
Press Power to skip Fast Test Cycle and advance to the next level.
Press Start/Pause to enter Fast Test cycle.
Once Fast Test Cycle is selected the DishDrawer goes into standby mode and 5 minutes will be showing on the
display. The test cycle is started by pushing Start/Pause and the following components are run during the 5 minute
cycle that follows:- Lid motors, fill valve, wash motor, element, drain motor.
Press Power to Exit at any time.
5.1.6 Continuous Cycle Test Mode
In this level the DishDrawer can be run continuously in any wash cycle. Once the cycle has finished, the DishDrawer
automatically restarts the same wash cycle.
Press Power to skip Continuous Cycle. As this is the last level, doing this will exit diagnostics.