Installation instructions
Dimensions and clearances
The cooker must be installed no less than 2” (50 mm) away from any side walls which exceed the
height of the cooktop.
The cabinetry surrounding the cooker must be made of heat-resistant material and must be able
to withstand temperatures of 150 °F (65 °C) above room temperature.
Do not install the cooker near flammable materials (eg curtains).
If you stand the cooker on a pedestal, make sure you provide safety measures to keep it in place.
Grounded outlet: should be located from the left to the right side of the range; from 5” 7/16 (138
mm) to 6” 1/8 (155.5 mm) [depending on feet regulation] from the floor.
The electric cord with 4-prong ground plug (NEMA 14-50P) shall have a minimum length of 48”
(1220 mm) beyond the back of the appliance.
Locating the area for electrical connection