Fisher & Paykel OR90SDBGFX Oven User Manual


 
14
Adjusting the minimum burner setting
Check whether the flame spreads to all burner ports when the burner is lit with the gas valve set
to the minimum position.
If some ports do not light, increase the minimum gas rate setting. Check whether the burner
remains lit even when the gas valve is turned quickly from the maximum to the minimum
position.
If the burner does not remain lit, increase the minimum gas rate setting.
To adjust the minimum gas rate setting:
Semi-rapid and triple-ring burners:
1
Turn on the burner.
2
Turn the valve to the MINIMUM position.
3
Take off the dial.
4
Using a small flat screwdriver, turn the screw (see Fig. 17) to the correct regulation.
Inside crown of dual burner:
1
Turn on the burner.
2
Turn the valve to the MINIMUM position of the inner crown only.
3
Take off the dial.
4
Using a small flat screwdriver, turn the screw (see Fig. 18) to the correct regulation.
Outside crown of dual burner:
1
Turn on the burner.
2
Turn the valve to the MINIMUM position of the inner and outer crowns.
3
Take off the dial.
4
Using a small flat screwdriver, turn the screw (see Fig. 18) to the correct regulation.
Note: for LPG, the regulation screw is normally tightened up.
Fig. 17 Adjusting the minimum burner setting:
semi-rapid and triple-ring wok burner
Fig. 18 Adjusting the minimum burner setting:
dual burner
regulation screw
Installation instructions
regulation screw
regulation screw
(inside crown)
regulation screw
(outside crown)