Frymaster 45 Series Fryer User Manual


 
1-6
1.5 Cleaning the Gas Valve Vent Tube
1. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened
for ease in removal.
2. Pass a piece of ordinary binding wire (.052 inch diameter) or equivalent through the tube to re-
move any obstruction.
3. Remove the wire, then blow through the tube to ensure it is clear.
4. Reinstall tube and bend it so that the opening is pointing downward.
1.6 Adjusting Burner Ceramic Target Spacing and Alignment
DANGER
Drain the frypot or remove the handle from the drain valve before proceeding further.
Proper spacing of the top edge of the burner ceramic targets is ¾ inch (13 mm) from the frypot side.
To adjust target spacing, bend the brackets to which they are attached away or toward the frypot to
the proper distance. (A length of board of the proper thickness is useful as a gauge to verify spacing
and alignment.)
1.7 Calibrating the Thermostat Control
NOTE: The fryer control panel must be hinged down from the control panel mounting frame to per-
form thermostat calibration. In order to hinge the control panel down, the thermostat knob must be
removed from its shaft. It is secured with a setscrew located opposite the index mark on the knob.
1. Fill the frypot to the lower OIL-LEVEL line with cooking oil/shortening. If solid shortening is
used, it must be pre-melted before starting the calibration procedure.
2. Ensure the fryer ON/OFF Switch is in the OFF position, then light the pilot. (Refer to Chapter 3
of the 45 Series Gas Fryer Installation and Operation Manual for detailed lighting instructions.)
3. Insert a good grade thermometer or pyrometer into the frypot so that it touches the thermostat
guard.
4. Loosen the setscrew and stop screw securing the ther-
mostat shaft extension to the flexible shaft. Remove
the extension to expose the slot in the end of the flexi-
ble shaft.
5. Place the fryer ON/OFF switch in the ON position.
NOTE: If the burner does not light at this time, it
does not mean the thermostat is defective!
Use a small flat-tipped screwdriver to slowly turn the flexible shaft counterclockwise until the
burner lights. Turning the shaft counterclockwise causes the burner to light and clockwise
causes it to shut off.
Stop screw
Locking nut
Setscrew