Frymaster 45 Series Fryer User Manual


 
1-10
1.8.5 Replacing the High-Limit Thermostat in Fryers with Other Than Thermostat
Controls
1. Disconnect the fryer from the electrical power
supply.
2. Drain the frypot.
3. Remove the screws from the upper left and
right corners of the controller panel. The con-
troller is hinged at the bottom and will swing
open from the top.
4. Unplug the wiring harness and disconnect the
grounding wire from the the controller.
5. Remove the controller from the fryer by lifting it from the hinge slots in the fryer control panel
frame.
6. Remove the two screws from the base of the interface board mounting bracket.
7. Disconnect the 12-pin plug from the back of the interface board and lay the board in the right
end of the compartment with all other wires still connected.
8. Remove the 12-volt transformer and lay it in the right end of the compartment with wires still
connected.
9. Remove the high-limit thermostat wires from the gas valve pilot coil and pull them up through
the control shield.
10. Unscrew the high-limit thermostat from the frypot and remove.
11. Apply Loctite™ PST56765 thread sealant or equivalent to the replacement thermostat’s threads
and screw it into the frypot.
12. Attach the appropriate terminals (furnished in the replacement thermostat kit) to the thermostat
leads.
13. Reverse steps 1 through 9 to complete installation of the replacement thermostat.
1.8.6 Replacing the Heat Mode Indicator Light in Fryers with Thermostat Controls
1. Disconnect the fryer from the electrical supply.
2. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws
from the upper left and right corners of the control panel. The control panel is hinged at the bot-
tom and will swing open from the top.
Unplug
harness
Disconnect
grounding wire