5-2
ON UNIT WITH AUTOFILL,
COOKPOT DID NOT FILL
WHEN UNIT WAS
TURNED ON. WATER
SUPPLY TO UNIT
VERIFIED TO BE ON.
Did anything
appear in controller
display when unit was
turned on?
Disconnect unit from
electrical power. Check
the left 5-amp fuse in
component box. Replace
fuse if blown then attempt
to operate.
Did unit begin
to fill?
Probable causes are shorted
upper water level sensor, failed
water solenoid, or loose/
damaged wiring. Call FASC.
No
No
NOTE: IF AUTOFILL WORKS
BUT AUTOSKIM DOES NOT,
PROBLEM IS A FAILED
CONTROLLER. ORDER
REPLACEMENT FROM FASC
OR DISTRIBUTOR.
Clean the water
level sensors.
Is another
controller, known
to be working,
available?
Substitute the controller
known to be working for
the suspect controller and
attempt to operate unit.
Yes
No
Problem resolved.Yes
Yes
Yes
Problem is beyond
the scope of operator
troubleshooting. Call
FASC.
No
No
Problem is a failed
controller. Order
replacement from
FASC or distributor.
Yes
Did unit begin
to fill?
Did unit begin
to fill?