2-2
2.2 Caster/Leg Installation
Depending upon the specific configuration ordered, your unit might have been shipped without in-
stalled casters or legs. If casters or legs are installed, you may skip this section and proceed to Sec-
tion 2.3, Pre-Connection Preparations.
If your unit requires the installation of casters/legs, install them in accordance with the in-
structions included in your accessory package.
2.3 Pre-Connection Preparations
After the unit has been positioned in the area where it will be used, ensure the following have been
accomplished before connecting the unit to the electrical power source:
1. This equipment must be stabilized by installing restraining chains on units equipped with
casters or anchor straps on units equipped with legs. Follow the instructions shipped with
the casters/legs to properly install the chains or straps.
2. Level units equipped with legs by screwing the legs out approximately 1 inch, then adjusting
them so that the unit is level.
For units equipped with casters, there are no built-in leveling devices. The floor where the
unit is to be installed must be level.
3. Install the basket lift arm (on units so equipped) on the lift rod (located at the top rear of the
cabinet) so that the basket lift roller guides the lift arm.
NOTE: Some adjustment of the roller may be necessary for free movement of the basket lift
arm.
4. Connect the water hose to the fitting at the rear of the unit.
DANGER
The maximum allowable incoming water pressure for all units is 80 PSI (56.3 kg/cm
2
).
The maximum allowable incoming water temperature for all units is 180ºF (82ºC).
NOTE: Either hot or cold water may be connected to the unit. However, connecting hot
water will minimize the time required to bring the unit to boil when filling with fresh water.
NOTE: In order for the water level sensors to work properly, a certain amount of mineral
content in necessary in the water. For that reason, purified, deionized, or highly filtered wa-
ter should not be used.
5. Connect the desired drain plumbing to the drain valve.