6-17
GM
C
N.C. N.O.
MICRO
SWITCH
GEAR
MOTOR
CONNECTOR
LINE
LOAD
CONTACTOR
COIL
SOLENOID
1 2 3 4 5 6 7 8 9101112131415
1 2 3 4 5 6 7 8 9101112131415
13 57 911
2 4 6 8 10 12
1C 2C 4C 7C 9C 10C 12C
1C1 1C2 1C3
1HV 2HV 3HV
16C
24C
11C
2
5
7
71C
8C
COMPUTER CONTROL
1C
BASKET LIFT RELAY
PROBE
LOW
WATER
SENSOR
HIGH
WATER
SENSOR
TRANSFORMER
8050462C
HOT
COM
POWER IN
24VAC GND.
NC HEAT
NO VOLTAGE
WHEN HEATING
24VAC WHEN
OFF
NC
WATER
FILL
GROUND WHEN
FILLING 24VAC
WHEN NOT
FILLING
NC
WATER LEVEL PROBES
DO NOT MEASURE
BASKET LIFT
SD
3 TO 5
VOLTS
WHEN SOUNDING
0 VOLTS WHEN
BASKET IS DOWN
13 TO 17 VDC
WHEN BASKET
IS UP
13 TO 17
VDC
TEMPERATURE
PROBE
2 TO 3
VOLTS DC
DEPENDING
ON THE
WATER
TEMPERATURE
NO VOLTAGE
NC
ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING
24VAC 50 VA.
120 VAC
COM
24 VAC
24VDC
A B
COM
NC
NO
24 VAC
BASKET LIFT SHOWN
IN UP POSITION
SOUND DEVICE
1
253 46
TEMP.
VRELAY
XX
13C 14C
43C
44C
OPTIONAL
AUTOFILL
71C
11C
5 AMP
FUSE
TYPE 3AG
BLACK
WHITE
GRN
120 VAC
CORDSET
3C
HIGH LIMIT
C
5C
N.C.
71C
71C
11C
IN-LINE SPLICE
IN-LINE
SPLICE
15C
480/120VAC DUAL VOLTAGE CONFIGURATION
L1 L2 L3
3 PHASE 3 WIRE
FIELD CONNECTION