Heatcraft Refrigeration Products PRO3 Refrigerator User Manual


 
PRO
3
Side Mount Packaged Refrigeration System Installation and Operations Manual, May 2008 19
PRO
3
Side Mount Packaged Refrigeration System
Model
Box Temperature
Voltage MCA MOPD Evaporator CFM
Dimensions
Figure
35°F 38°F
PST070H6B* 6,641 6,968 208-230/1/60 15 20 625 A
PST090H6B* 8,643 9,064 208-230/1/60 15 20 625 A
PST131H6B* 12,448 13,107 208-230/1/60 15 20 1,350 B
PST147H6B* 14,081 14,758 208-230/1/60 15 20 1,350 B
TABLE 2 Model PST | Cooler Application | Air Defrost | BTUH at 95°F Ambient Temperature
Model 35°F Box Temperature Voltage MCA MOPD
Evaporator
CFM
Dimensions
Figure
PST066M6B* 6,641 208-230/1/60 15 20 625 A
PST086M6B* 8,643 208-230/1/60 15 20 625 A
PST124M6B* 12,448 208-230/1/60 15 20 1,350 B
PST141M6B* 14,081 208-230/1/60 15 20 1,350 B
Model
Box Temperature
Voltage MCA MOPD
Evaporator
CFM
Dimensions
Figure
0°F -10°F -20°F
PST034L6B* 4,746 3,444 2,260 208-230/1/60 15.0 20 625 A
PST051L6B* 6,530 5,121 3,720 208-230/1/60 15.0 20 625 A
PST057L6B* 7,541 5,735 3,918 208-230/1/60 15.0 20 1,350 B
PST077L6B* 10,002 7,716 5,689 208-230/1/60 20.7 35 1,350 B
Model Refrigerant
Refrigerant
Charge (oz.)
Approximate Net Weight
lbs. kg
Coolers
PST070H6B* R-404A 36 260 118
PST090H6B* R-404A 36 265 120
PST131H6B* R-404A 40 320 145
PST147H6B* R-404A 40 325 148
Coolers with electric defrost
PST066M6B* R-404A 36 260 118
PST086M6B* R-404A 36 265 120
PST124M6B* R-404A 40 320 145
PST141M6B* R-404A 40 325 148
Freezers
PST034L6B* R-404A 36 260 118
PST051L6B* R-404A 36 265 120
PST057L6B* R-404A 40 320 145
PST077L6B* R-404A 40 325 148
* H for PSC, E for EC motor on evaporator section only.
TABLE 3 Model PST | Cooler Application | Electric Defrost | BTUH at 95°F ambient temperature
TABLE 4 Model PST | Freezer Application | Electric Defrost | BTUH at 95°F ambient temperature
Performance, Capacities and Specications
TABLE 5 Model PST | Specications
WARNING: This equipment may contain a substance that harms public health and the environment by destroying ozone
in the upper atmosphere. Venting of certain refrigerants to the atmosphere may be illegal in your location. Refrigerant
recovery devices should be used when installing or servicing this product. Consult your local codes for requirements in
your location.
WARNING: Refrigerant can be harmful if it is inhaled. Refrigerant must be used and recovered responsibly. Failure to