Henny Penny FM05-061-A Convection Oven User Manual


 
CAUTION
Risk of crushing fingers due to rotating fan
Disconnect the unit from the power supply before you remove
the ventilation plate.
Do not operate the unit without the ventilation plate.
1. Remove the screws in the middle of the ventilation plate.
2. Open the front catch.
3. Fold the ventilation plate towards the rear wall.
4. Open the rear catch.
5. Slightly raise the ventilation plate and remove it.
6. Clean the cooking chamber behind the ventilation plate.
7. Push the ventilation plate onto the upper bolts.
8. Close the rear catch.
9. Fold the ventilation plate towards the side wall.
10. Close the front catch.
11. Check the catches.
12. Replace the screws in the middle of the ventilation plate.
73Operating manual
Global Foodservice Solutions
Cleaning