2-14. FILTERING SYSTEM The filtering system consists of the filter valve, motor and filter pump
assembly, filter screen assembly, and tubing.
Shortening with temperature in excess of 200 OF flows
through this filter rinse hose. Heat causes the rubber hose
to age and deteriorate. The hose and fittings should be
checked daily. If aging or discoloration is seen the hose
should not be used. Severe burns may result if this rinse
hose assembly leaks or ruptures.
1. Close the filter valve.
2. Turn the pump switch to the OFF position.
3. Detach the hose BEING CAREFUL, AS THE HOSE AND
FITTINGS WILL BE HOT, USE A COLD WET CLOTH.
NOTE
This hose is not connected to the fryer during normal opera-
tion.
Installation
593
1. Attach the filter rinse hose with its quick disconnect female fitting
to the other half male fitting inside the door, next to the filter valve
handle.
2. To do this slide back the spring ring on the female end of the
quick disconnect fitting and let it snap into place over the
other half male fitting.
3. With a quick tug on the hose, insure the quick disconnect is
locked into position.