Henny Penny OE-100 Fryer User Manual


 
Henny Penny Model OE-100
2-14
2-15. FILTER VALVE The filter valve is a 3/8 inch two-way stainless steel ball valve. If this
valve should develop leaks the entire valve must be replaced.
To avoid electrical shock or other injury before starting this
procedure move COOK/PUMP SWITCH to OFF position.
Disconnect main circuit breaker at the circuit breaker box
and unplug service cord from wall receptacle.
1. Drain the shortening from the frypot.
2. Remove the filter drain pan from the fryer.
3. Remove the cotter pin, handle, and extension rod.
4. Remove the pipe from between the filter pump and valve.
5. Remove tee and nipple from valve.
6. Use an adjustable wrench and remove the valve.
7. Replace the valve and reassemble in reverse order.
2-16. FILTER PUMP
REPAIR
The two most common causes for a fryer's inability to pump shortening
is that the pump is clogged with breading or solid shortening has
cooled and solidified in the lines and pump. This then could cause the
thermal reset to kick the motor out and the reset button on the back of
the motor needs reset.
To avoid electrical shock or other injury before starting this
procedure move COOK/PUMP SWITCH to OFF position.
Disconnect main circuit breaker at the circuit breaker box
and unplug service cord from wall receptacle.
1. Loosen the four allen head screws on the end of the pump and
remove the cover.
2. The inside is now exposed leaving a rotor and five teflon rollers.
Clean the rotor and rollers.
593