Henny Penny OE-100 Fryer User Manual


 
Henny Penny Model OE-100
2-2
2-4. THERMAL SENSOR The thermal sensor determines the shortening temperature. If a mal-
function does occur, an E6 will be displayed on the digital readout.
Turn unit to OFF position, then back to COOK position. If E6 is still
displayed, the thermal sensor must be replaced by following these
steps:
1. Remove electrical power supplied to fryer.
Place POWER switch in the OFF position and unplug the
power cord or remove power from the fuse or breaker box.
2. Drain the shortening from frypot.
3. Remove two decorative strips located on each side of control
panel and let control panel swing out.
593
2-3. REMOVING THE
CONTROL PANEL
(Continued)
3. Panel will now swing out with hinge located on left side of panel.
4. Pulling down on the spring loaded hinge pin, pull control panel
straight out to completely remove.
NOTE
When completely removing control panel, all wiring must be
unplugged from control panel. Be sure to mark wires before
removing.
5. Install panel board by reversing order.