Henny Penny OE-100 Fryer User Manual


 
2-7
Henny Penny Model OE-100
2-7. CONTACTORS
The following checks are performed with the wall circuit
breaker closed and the Power switch in the ON position.
Extreme caution should be taken. Make connections before
applying power, take reading, and Remove power before
removing meter leads.
1. With power applied, increase setpoint temperature setting allow-
ing heat contactor to activate.
Test Points Results
Heat Contactor The voltage
from terminal 34 to 35 should read the
from terminal 35 to 36 same at each
from terminal 34 to 36 terminal.
Test Points Results
Primary Contactor It should
from terminal 27 to 28 correspond to
from terminal 28 to 29 the voltage
from terminal 27 to 29 rating stated on
the data plate.
If either contactor is defective, it must be replaced as follows:
1. Remove electrical power supplied to the fryer by unplugging
or opening the wall circuit breaker.
2. Remove only those wires directly connected to the contactor
being replaced. Label the wires.
3. Remove the two mounting screws on the base plate and
remove contactor.
4. Install the new contactor and tighten the two mounting
screws.
5. Connect the labeled wires to their respective positions.
6. Install the control panel.
7. Reconnect power to the fryer and test the fryer for proper
operation.
593