Henny Penny OE-100 Fryer User Manual


 
Henny Penny Model OE-100
2-16
2-18. PUMP AND MOTOR
REPLACEMENT
1. To replace the pump and motor assembly, insure the main power
has been removed from the fryer.
To avoid electrical shock, injury or burns before starting
this procedure move COOK/PUMP SWITCH to OFF
position. Disconnect main circuit breaker at the main
circuit breaker box and unplug service cord from wall
receptacle.
2. Remove the cover from the junction box and remove the wire
nuts attaching wires leading into the flexible conduit going to
the motor.
3. Loosen the two screws securing the flexible conduit going to
the motor.
4. Remove tubing to the pump.
5. Remove hardware attaching the motor to the motor hase
bracket and remove motor and pump assembly.
2-19. COOLING FAN
MAINTENANCE
The cooling fan on the OE-100A open fryer reduces the amount
of heat behind the panel, and if the heat does become excessive,
"E-4" will show on the display.
The PC boards on the control panels can be damaged by exces-
sive amount of heat so it is important that the cooling fan is
operating properly and has good air flow.
To prevent an "E-4" reading, which will shut the heat off to the
fryer, follow the following steps.
ONCE A MONTH:
1. Turn power switch to the "OFF" position.
2. Open door to bottom of fryer.
3. Locate metal fan guard situated in the left front, under the
control panel.
4. Clean any lint and dirt from fan guard.
294