Henny Penny OE-100 Fryer User Manual


 
2-5
Henny Penny Model OE-100
2-6. HEATING ELEMENTS
NOTE
Heating elements are available for 208 and 480 voltage.
Check the data plate to determine the correct voltage.
If the shortening's temperature recovery is very slow or at a
slower rate than required, this may indicate defective heating
element(s). An ohmmeter will quickly indicate if the elements are
shorted or open.
1. Remove electrical power supplied to unit.
Place POWER switch in the OFF position and unplug the
power cord or open the wall circuit breaker.
2. Remove the control panel. Refer to Section 2-3.
3. Perform an ohm check on one element at a time, with wires
disconnected from element. If the resistance is not within
tolerance, replace the element.
Resistance
Voltage Wattage in Ohms (Cold)
480 7333 27.5
415 7333 6.9
380 7333 18.8
240 7333 6.9
208 7333 5.6
480 4500 51.2
415 4500 11.75
380 4500 N/A
240 4500 11.75
208 4500 9.61
593
2-5. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
15. With excess capillary line pulled out, tighten smaller nut.
NOTE
Tighten nut to snug only. Too tight will damage
capillary line.
16. Replace front panel.
17. Refill with shortening.