Hobart KA7E Convection Oven User Manual


 
– 11 –
INITIAL STARTUP
Power On
Toggle the Main Power switch on the front panel of the oven to the ON
position; the red indicator light on the switch comes on (Fig. 15).
Idle Mode
When the oven is rst turned on, the display shows the time of day 
and the last operated program number. Any programmed steps for
the selected program are indicated by illuminated step LEDs. The
interior oven lights are off.
Setting the Clock
The oven's clock is preset at the factory to run two 12-hour cycles
for A.M. and P.M. as standard. The clock can be reprogrammed to
run as a 24-hour clock by your Hobart service technician.
To set the clock, begin from idle mode.
•  Press 
CLOCK
.
The time display goes blank.
The AM or PM light blinks.
•  Enter the time of day (HH:MM) using the number keys.
•  Press 
CLOCK
to toggle A.M. or P.M. (not necessary if clock is
programmed for 24-hour operation).
•  Press 
ENTER
to accept a valid entry. The control returns to idle
mode.
•  If a nonvalid value such as 10:95 is in the time display when 
ENTER
is pressed, the beeper sounds twice and the time display goes
blank.
Changing Temperature Readings to Celsius
The oven is preprogrammed for temperatures to read in Fahrenheit
degrees as standard. The oven can be reprogrammed for Celsius
temperature readings by your local Hobart Service ofce.
P
7 8 9
4 5 6
1 2 3
ENTERCLEAR
START
CLOCK
ADD
5
STOP
TEMPERATURE
TIME
F
C
PROGRAM
AM
PM
STEP
1 2 3 4
MANUAL
0
CLEAN
P 0
9:25
Fig. 15
ON
OFF