Hobart ML-138211 Dishwasher User Manual


 
– 18 –
Deflector Pan
OnCLemachinesonly,assembledeectorpanoverdrainconectionnuts.Panis
removable for cleaning.
On CLeRmachines, assemble deectorpan over twostuds locatedclosest to
unload section of blower-dryer.
Adjusting the Vents on the Blower-Dryer and Dishwasher (hood or open canopy)
CLe-Series
To maintain good wash tank temperature, it is critical to adjust the vents to reduce
airowmovementcausedbythedryerfan.Therststepistoadjustdishwasher
vent system per Exhaust Spec. To help maintain tank heat, adjust the entrance and
exit dampers so the draw stops vapor from escaping into room. Excess draw can
pull tank heat from the entrance or exit of machine. Next, set the blower dryer vent
angle (located at the exit end of the blower dryer). Without removing any panels,
the damper can be adjusted by reaching into the chamber and rotating damper.
Adjust the damper to approximately 60 degrees. Next, let the dishwasher reach
minimal temperature, then turn the dishwasher ON and observe both the entrance
and discharge of the dishwasher. The curtains should be hanging nearly straight
down. If the discharge curtain is moving excessively make the following changes:
CLeR-Series
For CLeR-Series vent adjustments, refer to the CLe-Series dishwashers Instructions
Manual (F-44127, Rev. C, November 2012).
CLeR-Series
Fig. 25A
4" X 16"
VENT
CONNECTOR
PANT-LEG DUCT
ENTRANCE
VENT STACK
DAMPER
EXIT
VENT STACK
DAMPER
INTERNAL VENT
SHOULD REMAIN
OPEN UNLESS
AIRFLOW ADJUSTMENT
IS NECESSARY
DEFLECTOR PAN