SANITIZING SYRUP SYSTEMS
Syrup systems should be sanitized every 90 days as instructed following Sanitizer Manufacturers
recommendations.
COOLING UNIT MAINTENANCE
COOLING UNIT AIR INTAKE AND EXHAUST FILTERS
CAUTION: Air filters on the Cooling Unit must be removed and cleaned every 30 days as
instructed. Excessive accumulation of dust, lint, and grease on the air filters will restrict
airflow through the Unit which will cause the refrigeration system to overheat.
The Cooling Unit cabinet is equipped with are intake and exhaust filters which allow air to circulate through the
cabinet to cool the compressor. Air filters must be cleaned every 30 days as instructed. Area around Cooling
Unit must be kept free of obstructions at all times for proper air circulation through the Unit.
CHECKING ICE WATER BATH
Note: Some Cooling Units are equipped with a water tank water level float control. A gurgle heard from
the Cooling Unit indicates water level in water tank is low. This indicates the water level float control is
not operating properly and must be replaced.
A gurgle heard from the Cooling Unit indicates water level in water tank is low and more water should be added
to the tank for maximum product cooling. Periodically check, and if necessary, add water to the water tank as
instructed.
COOLING UNIT CARBONATOR MAINTENANCE
Lubrication.
Carbonator water pump motor bearings must be oiled periodically as instructed.
DOUBLE LIQUID CHECK VALVE ASSEMBLIES YEARLY MAINTENANCE (OR AFTER
WATER SYSTEM DISRUPTIONS).
(see Figure 2)
The two double liquid check valve assemblies are located in plain water lines connected between the plain
water cooling coils and the carbonated water tank. The double liquid check valve assemblies must be inspected
and cleaned at least once a year under nor work, earthquake, etc.) Inspect and clean double liquid check valve
assemblies as instructed.
COOLING UNIT CARBONATED WATER CIRCULATING PUMP MOTOR LUBRICATION
Carbonated water circulating pump motor bearings must be oiled periodically as instructed.