Cornelius 10 Refrigerator User Manual


 
32300614000
Trouble RemedyProbable Cause
ONLY CARBONATED WATER
DISPENSED (cont).
E. Dispensing valve syrup flow
regulator, soft drink tank quick
disconnect, or syrup lines
restricted.
E. Sanitize syrup system as
instructed.
ONLY SYRUP DISPENSED. A. Plain water inlet supply line
shutoff valve closed.
A. Open plain water inlet supply line
shutoff valve.
B. CARBONATOR MOTOR
power switch in ‘‘OFF’’
position.
B. Place switch in ‘‘ON’’ position.
C. Water filter clogged. C. Replace water filter.
WARM PRODUCT BEING
DISPENSED.
A. Carbonated water circulating
pump CIRCULATING MOTOR
power switch in ‘‘OFF’’
position.
A. Place circulating pump
CIRCULATING MOTOR power
switch in ‘‘ON’’ position.
B. Inoperable carbonated water
circulating pump or motor.
B. Replace pump or motor.
WATER PUMP MOTOR WILL
NOT OPERATE.
A. Inoperative water pump motor. A. Replace water pump motor.
B. Water safety thermostat
inoperative.
B. Replace safety thermostat.
C. Loose connections and/or
open electrical circuit.
C. Tighten connections and/or repair
open circuit.
D. Overheated motor cut off by
thermal overload protector.
D. Check for proper line voltage.
Check for restricted pump
discharge.
E. Water pump binding (new or
replacement pumps only.)
E. Remove water pump from motor,
rotate pump or motor shaft 180
degrees, then recouple pump to
motor.
F. Inoperative liquid level sensing
probe.
F. Replace liquid level sensing
probe.
G. Inoperative liquid level sensing
PC board.
G. Replace liquid level sensing PC
board.
H. No 24 VAC to liquid level
sensing PC board.
H. Check electrical wiring and
transformer for 24 VAC output.
WATER PUMP MOTOR WILL
NOT SHUT OFF.
A. Inoperative liquid level sensing
probe.
A. Replace liquid level sensing
probe.
B. Inoperative liquid level sensing
PC board.
B. Replace liquid level sensing PC
board.
C. Liquid level sensing probe
wired wrong.
C. Correct liquid sensing probe
wiring.
D. Leak in carbonated water
system.
D. Repair leak in carbonated water
system.
ERRATIC CYCLING OF
CARBONATOR.
A. Inoperative liquid level sensing
probe.
A. Replace liquid level sensing
probe.
B. Inoperative liquid level sensing
PC board.
B. Replace liquid level sensing PC
board.