Cornelius 10 Refrigerator User Manual


 
27 300614000
3. Connect full tank of syrup into syrup system.
SYRUP FLAVOR CHANGE
1. Perform sanitizing procedure on syrup system syrup flavor change will be made on.
2. Check soft drink tank quick disconnects for sticky or restricted operation. Wash disconnects in warm water.
3. Connect full tank of new flavor syrup into syrup system.
CLEANING CO
2
SYSTEM GAS CHECK VALVES
SECONDARY CO
2
REGULATORS AND CO
2
MANIFOLD CO
2
GAS CHECK VALVES
(see Figures 2 and 7)
The secondary CO
2
regulators and CO
2
manifold CO
2
gas check valves must be inspected and serviced at
least once a year under normal conditions and after any servicing or disruption of the CO
2
system. ALWAYS
REPLACE BALL SEAT (QUAD RING SEAL) EACH TIME GAS CHECK VALVES ARE SERVICED.
COOLING UNIT CO
2
INLET LINE CO
2
GAS CHECK VALVE
(see Figures 2 and 7)
CO
2
inlet line CO
2
gas check valve, located inside Cooling Unit, must be inspected and serviced at least once a
year under normal conditions and after any servicing or disruption of the CO
2
system. ALWAYS INSTALL NEW
BALL SEAT (QUAD RING) SEAL EACH TIME GAS CHECK VALVE IS SERVICED.