Cornelius 10 Refrigerator User Manual


 
17 300614000
SERVICE AND MAINTENANCE
The Remote Rooftop Condenser Coil and Fan Assembly Condenser Coil must be cleaned every 30 days.
Circulating air, required to cool the coil, is drawn in at bottom and is exhausted out through top of Unit. Clean
the condenser coil as follows:
1. Disconnect electrical power to Cooling Unit at disconnect switch, then disconnect electrical power from
Remote Condenser Coil and Fan Assembly at disconnect switch.
2. Clean bottom side of condenser coil using vacuum cleaner, whisk broom, or soft-bristle brush to remove
any debris from coil.
3. Check and make sure fan blade moves freely and is not touching any surfaces, are not bent, or out of
balance. check and make sure wire guard is properly installed and securely fastened.
4. Check and make sure roof area immediately surrounding Unit is free and clear of any debris that may have
collected such as leaves, paper, trash, etc.
5. Restore electrical power to Cooling Unit at disconnect switch, then connect electrical power to Remote
Condenser Coil and Fan Assembly at disconnect switch.
COOLING UNIT MAINTENANCE
PERIODIC CLEANING
Periodically wash all external surfaces of Cooling Unit, rinse with clean water, then wipe dry with a clean soft
cloth. DO NOT USE ABRASIVE TYPE CLEANERS.
CLEANING COOLING UNIT AIR INTAKE AND EXHAUST FILTERS.
(see Figure 5).
This section describes Service and Maintenance procedures to be performed on Cooling Unit and Remote
Condenser Coil and Fan Assembly.
WARNING: Disconnect electrical power to Cooling Unit and Remote Condenser Coil and
Fan Assembly to prevent personal injury before attempting any Cooling Unit or Remote
Condenser Coil and Fan Assembly internal maintenance. Only qualified personnel should
service internal components or electrical wiring.
PREPARING COOLING UNIT FOR SHIPPING, STORING, OR RELOCATING
CAUTION: Before shipping, storing, or relocating this Unit, the syrup systems must be
sanitized and all sanitizing solution must be purged from the syrup systems. All water must
also be purged from the plain and carbonated water systems. A freezing ambient
environment will cause residual water in the Unit to freeze resulting in damage to internal
components.
PERIODIC INSPECTION
Check entire system for leaks or damaged components. Repair as necessary.