REPLENISHING CO
2
SUPPLY
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
NOTE: When indicator on CO
2
cylinder primary CO
2
regulator assembly 1800-psi gage is in shaded
(‘‘change CO
2
cylinder’’) portion of dial, CO
2
cylinder is almost empty and should be changed.
1. Fully close (clockwise) CO
2
cylinder valve.
2. Slowly loosen primary CO
2
regulator assembly coupling nut allowing CO
2
pressure to escape, then remove
regulator assembly from empty CO
2
cylinder.
3. Unfasten safety chain and remove empty CO
2
cylinder.
FIGURE 7. CO
2
GAS CHECK VALVE
WARNING: To avoid personal injury and/or property damage, always secure CO
2
cylinder in
upright position with safety chain to prevent it from falling over. Should valve become
accidentally damaged or broken off, CO
2
cylinder can cause serious personal injury.
4. Position CO
2
cylinder and secure with safety chain.
5. Make sure gasket is in place inside primary CO
2
regulator coupling nut, then install regulator on CO
2
cylinder.
6. Open (counterclockwise) CO
2
cylinder valve slightly to allow lines to slowly fill with gas, then open valve
fully to back-seat valve. (Back-seating valve prevents leakage around valve shaft).
REPLENISHING SYRUP SUPPLY
NOTE: The following instructions are applicable only when replenishing same flavor syrup. Refer to
SYRUP FLAVOR CHANGE when changing syrup flavor.
1. Disconnect empty soft drink tank from syrup system.
2. Check soft drink tank quick disconnects for sticky or restricted operation. Wash disconnects in warm water.