Cornelius PR150 BC Beverage Dispenser User Manual


 
10620918702
1. Remove cover from the dispensing valve by lifting the front cover up 1/4 inch and pulling forward.
2. Install syrup diversion tube assembly on the dispensing valve by pushing rubber end of the syrup diversion
tube onto the syrup outlet of the inner nozzle.
3. Measure the water flow rate by dispensing water into a graduated cup for a set period of time.
NOTE: Adjusting screw stops are built into the valve to prevent leakage when the screws are adjusted
too far clockwise. Stop adjusting clockwise when turning resistance increases. Turn the screw coun-
terclockwise 1–1/2 turns after the stop are contacted.
4. Turn the water flow regulator adjusting screw to the left (counterclockwise) to decrease the water flow rate
or turn the adjusting screw to the right (clockwise) to increase the water flow rate, then recheck the flow
rate. Adjustments should be no more than 1/4 turn at a time.
5. Remove syrup diversion tube from the dispensing valve, then install cover on the dispensing valve.
WATER FLOW
REGULATOR
SYRUP FLOW
REGULATOR
INNER NOZZLE
NOZZLE
SYRUP DIVERSION
TUBE
RATIO CUP
Counterclockwise
to Decrease
Clockwise
to Increase
FIGURE 3. UF-1 DISPENSING VALVE
ADJUSTING WATER-TO-SYRUP “RATIO” (BRIX) OF DISPENSED PRODUCT
(see Figure 3)
NOTE: Make sure the dispensing valve water flow rate is as desired before adjusting the valve for Wa-
ter-to-Syrup ‘‘Ratio’’ (Brix) of the dispensed product.
Adjust Water–to–Syrup “Ratio” (Brix) of the dispensed product by using ratio cup (P/N 311100000) and syrup
diversion tube assembly (P/N 319540000) as follows:
1. Remove cover from the dispensing valve by lifting front cover up 1/4 inch and pulling forward.