CorrectLP Gas Tank Use
LP gas gdllmodelsaredesignedfor usewitha
standard20 lb. LiquidPropaneGas(LPgas)tank,
not includedin gdllbox.Neverconnectyourgas
gdllto an LPgastankthatexceedsthiscapacity.A
tankof approximately12inchesin diameterby
18-1/2incheshighis the maximumsize LPgas
tankto use.You must use an "OPD" gas tank
which offers a listed Overfill Prevention Device.
This safety feature prevents tank from being over-
filled which can cause malfunction of LP gas tank,
regulator and/or grill.
The LP gas tank must be constructed and marked
in accordance with the Specifications for LP-Gas
Cylinders of the U.S. Department of Transportation
_D.O.T.) or the National Standard of Canada, CAN/
A-B339, Cylinders, Spheres and Tubes for Trans-
portation of Dangerous Goods; and Commission, as
applicable.
1. The LP gas tank has a shutoff valve, termi-
nating in an LP gas supply tank valve outlet,
that is compatible with a Type 1 tank con-
nection device. The LP gas tank must also
have a safety relief device that has a direct
connection with the vapor space of the tank.
2. The tank supply system must be arranged
for vapor withdrawal.
3. The LP gas tank used must have a collar
to protect the tank valve.
Proper Placement and Clearance of Grill
Never use your gas grill in a garage, porch, shed,
breezeway or any other enclosed area. Your gas grill is
to be used outdoors only, at least 24 inches from the
back and side of any combustible surface. Do net
locate this appliance underoverhead unprotected
combustible surfaces. Do not obstruct the flow of
ventilation air around the gas grill housing.
This outdoor gas grill is not intended to be installed in
or on recreational vehicles and!or boats.
Never connect an unregulated LP gas tank to
your gas grill. The gas regulator assembly
supplied with your gas grill is adjusted to have
an outlet pressure of 11" water column (W.C.)
for connection to an LP gas tank.
Only use the regulator and hose assembly
supplied with your gas grill. Replacement
regulators and hose assemblies must be those
specified by Sears.
Have your LP gas tank filled by a reputable
propane gas dealer and visually inspected and
re-qualified at each filling.
Never fill the gas tank beyond 80% full.
Have your propane gas dealer check the
release valve after every filling to ensure that
it remains free of defects.
Always keep LP gas tanks in upright position.
Do not store (or use) gasoline or other flammable
vapors and liquids in the vicinity of this gas grill.
LP gas tanks not connected for use must NOT be
stored on bottom shelf or in the vicinity of this or
any other gas grill.
Do not subject the LP gas tank to excessive heat.
Never store an LP gas tank indoors. If you
store your gas grill in the garage or other
indoor location, always disconnect the LP gas
tank first and store it safely outside.
LP gas tanks must be stored outdoors in a
well-ventilated area and out of the reach of
children. Disconnected LP gas tanks must not
be stored in a building, garage or any other
enclosed area.
When your gas gdll is not in use the gas
must be turned off at the LP gas tank.
The regulator and hose assembly can be seen
after opening the doors (if applicable), must be
inspected before each use of the grill. If there
is excessive abrasion or wear or if the hose is
cut, it must be replaced prior to the grill being
used again.
Keep the gas regulator hose away from hot
grill surfaces and dripping grease. Avoid unnec-
essary twisting of hose. Visually inspect hose
prior to each use for cuts, cracks, excessive
wear or other damage. If the hose appears
damaged do not use the gas grill. Call Sears
at 1-800-4-MY-HOME (1-800-469-4663) for a
Sears authorized replacement hose.
Never light your gas grill with the lid closed or
before checking to ensure the burner tubes are
fully seated over the gas valve orifices.
Never allow children to operate your gdll. Do
not allow children to play near your grill.
i WARNING
A strong gas smell, or the hissing sound of
gas indicates a serious problem with your
gas grill or the LP gas tank. Failure to
immediately follow the steps listed below
could result in a fire or explosion that could
cause serious bodily injury, death, or prop-
erty damage.
Shut off gas supply to the gas grill.
Turn the Control Knobs to OFF position.
Put out any flame with a proper fire extin-
guisher.
Open Grill Lid.
Get away from the LP gas tank.
Do not try to fix the problem yourself.
If odor continues or you have a fire you
cannot extinguish, call your fire department.
Do not call near the LP gas tank because
your telephone is an electrical device and
could create a spark resulting in fire and/or
explosion.
NOTE: The normal flow of gas through the
regulator and hose assembly can create a
humming noise. A low volume of noise is
perfectly normal and will not interfere with
operation of the grill. If humming noise is
loud and excessive you may need to purge
air from the gas line or reset the regulator
excess gas flow device. This purging proce-
dure should be done every time a new LP
gas tank is connected to your gdll. For help
call the Customer Service Helpline for assis-
tance, 8am - 8pm CST, Monday through
Friday 1-888-317-7642.
3