Liebherr 7082 532-00 Refrigerator User Manual


 
4
The ice maker is fitted in the freezer compartment of the combined
refrigerator-freezer. It must be connected to the mains water supply
to work. The descriptions below only relate to the ice maker and
the water connection to a solenoid valve. All the instructions and
details for the appliance as a whole are set out in the enclosed
operating instructions for the combined refrigerator-freezer.
The floor on which the appliance stands should be horizontal
and level. To compensate for any unevenness, adjust the height
of the feet with the open-ended wrench supplied. The combined
refrigerator-freezer must stand level.
Safety instructions and warnings
• Do not make the water connection whilst the combined refrig-
erator-freezer is connected to the electricity supply.
The connection to the mains water supply may only be made
by a trained plumber.
The water quality must comply with the drinking water di-
rectives of the country in which the appliance is used.
• The ice maker is designed exclusively to make ice cubes in
quantities required by a household and may only be operated
with water suitable for this purpose.
• All repairs and work on the ice maker may only be carried out
by customer service personnel or other trained personnel.
The first three batches of ice must not be consumed or
used. This applies both to using the appliance for the first
time and also to using it after it has not been used for a
lengthy period of time.
This ensures that the water supply
is purged.
The manufacturer cannot accept liability for damage caused
by a faulty connection to the mains water supply.
Instructions for trained personnel
Connection to the water supply
Please read the first three points of the safety instructions and
warnings before connecting the appliance to the mains water
supply.
The water pressure must be between 1,5 and 6 bar. The water
supply to the appliance must be through a cold water pipe that
can withstand the operating pressure and complies with the hy
-
giene regulations. For this, use the stainless steel hose supplied
(length 1.5 m).
An extension hose of either 1.5 m or 3 m is available from the
customer service department which must be assembled by
a technician.
A shut-off valve must be installed
between the hose line and the house
mains supply so that the water supply
can be stopped if necessary.
Before the appliance is used for the first time the system must
be bled of any air by a competent person (i.e. Plumber)
1. Open the shut-off valve for the water supply and check
the entire water system for leaks.
2. Insert the mains plug for the combined refrigerator-
freezer into the socket.
3. Move the combined refrigerator-freezer into its intended final
position. Ensure that the water supply pipe is not damaged
or kinked as you do this.
All equipment and devices used to supply the water to the
appliance must comply with the current regulations of the
country concerned.
Connect the angled section of the
stainless steel hose to the solenoid
valve. The water connection to the
appliance is via the solenoid valve on
the rear of the appliance. The connec
-
tion dimension is R 3/4.
Instructions for trained personnel
Position of the water connection
Position of the water connection if a 1.5 m
hose is used. This hose is supplied with the
appliance as standard.
Position of the water connection if a 3 m hose is used. This
hose is available from our customer service department.
Connect the straight section of the
supplied stainless steel hose to the
shut-off valve. There is a screen and
seal in the connector.