Liebherr 7082 532-00 Refrigerator User Manual


 
21
GB
- Have you opened the appliance too frequently and for too
long?
- Wait to see if the appliance goes back to the required tem-
perature by itself.
appears on the display
- A power failure or power cut has occurred, proceed as explained
in the section entitled “Power cut/FrostControl display“
The compressor runs for a long time
- This is completely normal and necessary on energy-saving
models. The speed regulated* compressor switches to a lower
speed when it requires a lower cooling capacity. Although this
means that the running timeincreases, to almost permanent,
in fact it is saving energy.
Customer services and type plate
If none of the above causes is present, and you cannot fix
the fault yourself, or if the temperature display is showing
“F0” to “F5” this means that: there is a fault. You should contact
your nearest customer services point (see directory enclosed).
Tell them of the fault message on your display and also the
Appliance designation 1
Index 2,
Serial no.. 3
of the type plate. This will
make it possible to pro-
vide fast and accurate
service. The type plate
is located inside the ap-
pliance to the left.
Keep the appliance
closed until customer
services can cometo
avoid any further loss
of cold.
Installation information
W The appliance can also be installed in a fitted kitchen.
If this is the case you first need to fit the kitchen unit door and
the niche in which the appliance will be positioned. These
are no longer required, because the fitted unit door is fitted to
the door of the appliance.
C
B
mm
max.
2100
A
539
557
560-570
550
min.
38
min.
38
90°
min.200 cm²
min.200 cm²
110
15
W Check the dimensions:
A B C
ICN 30 1772-1778 1769,5 695
IC 29 1574-1590 1574,5 549
W Use a spirit level to ensure that the niche cupboard is level.
If necessary, even it out by using base cauls. The base and
walls of the kitchen unit must be at right angles to one an-
other.
W The fridge/freezer must be installed only inside solid kitchen
fittings.
W It is essential that the ventilation cross-sections are main-
tained:
- The ventilation shaft at the rear of the unit must be at least 38
mm deep.
- A minimum of 200 cm
2
is necessary for the ventilation cross-
sections at the base of the unit and the surrounding unit.In
general the following applies: the larger the ventilation cross
section, the more energy the appliance will be able to save.
Before starting the installation:
W Remove the mains cable holder from the back of the
appliance.
W Use a cord to lay the mains cable.