Middleby Marshall PS555 Microwave Oven User Manual


 
147
SECTION 3 - SERVICING COMPONENTS
Figure 87
Figure 89
Figure 88
Support the wide end of the tube between two
pieces of wood so that the terminal end will not be
damaged.
Place a deep well socket over the new Tinnerman
clip.
Gently tap the socket with a hammer to push the
clip down and into place.
NOTE: When replacing the mercury contactor into
the oven, the wider tube ends must be pointing UP.
The tubes must ALWAYS be mounted in a vertical
position.