..."dn" appears in the temperature
display?
The demo mode is activated.
^
Call Customer Service.
. . . the appliance cannot be switched
off?
The safety lock is activated.
. . . the interior lighting in the
refrigerator section is not working?
^
Was the appliance door left open for
a long time? The lighting
automatically switches off if the door
has been open for approx.
15 minutes.
If that is not the reason, then the interior
lighting is defective.
^ Unplug the appliance, or turn off the
respective circuit breaker of the
house wiring system.
^
Remove the front panel.
^
Pull out the glass plate.
^
Unscrew the light bulb and replace it
with a new one.
Light bulb specifications:
110 - 120 V, max. 25 W, E 14 base.
^ Slide the glass plate in again.
^ Replace the panel and engage the
catches.
. . . the floor of the refrigerator
section is wet?
The drain hole is blocked.
^ Clean the condensate channel and
the drain hole.
If a malfunction cannot be corrected
using this troubleshooting guide,
please contact Miele Customer Ser
-
vice.
To prevent cold from escaping,
open the appliance doors as little as
possible until the malfunction has
been corrected.
Troubleshooting