Miele KFN 14943 SD ED Refrigerator User Manual


 
aadapter cabinet
bappliance
ckitchen cabinet
dwall
The appliance can be installed in any
fitted kitchen. To match the appliance
to the height of the fitted kitchen, a
suitable adapter cabinet a can be
installed over the appliance.
A ventilation gap of at least 2 inches
(50 mm) must be provided between the
adapter cabinet and the kitchen wall.
The ventilation cross-section below the
room ceiling must be at least 46 in
2
(300 cm
2
) so that warm air can escape
without obstruction. Otherwise the
appliance has to work harder, which
results in increased energy
consumption.
The ventilation cross-sections must
not be blocked or covered in any
way.
They also need to be
dusted/cleaned on a regular basis.
If installing with standard kitchen
cabinets (max. depth 580 mm), the
appliance can be set up directly next to
the kitchen cabinet. In that case the
side of the appliance door would
project 34 mm and the middle of the
appliance 55 mm beyond the front of
the kitchen cabinet. This allows the
appliance door to open and close
properly.
If the appliance is installed next to a
wall d, a gap of at least 55 mm is
needed on the hinge side between the
wall d and the appliance b. This
allows space for the handle when the
door is open.
Installing the appliance
60