; Electrical Connection MD-1000HT
1. Locate the control cabinet keys on the rear of the control cabinet.
2. Remove 1 key to unlock the cabinet; do not remove the other key.
3. Unlock the control cabinet and remove the cover.
4. Locate the power cable knock out and main terminal block on the left-side of the cabinet.
5. Locate the Machine Electrical Connection Data Plate mounted near the terminal block.
6. Connect the electric service to the dishwasher.
Warning:
Disconnect the main electric supply and place a tag at the fuse or disconnect switch
indicating that work is being performed on that circuit.
Warning:
The dishwasher must be electrically grounded according to all local codes
and regulations governing the installation of electrical service.
The MACHINE ELECTRICAL CONNECTION DATA PLATE is the certified authority for the
dishwasher power requirement
s. DO NOT use electrical data from any other source
unless an authorized factory represent
ative instructs you to use other data.
Cable knock-out
Machine Electrical
Connection Data Plate
Main terminal block
Powering the dishwasher without performing the Initial Start-up
may damage the dishwasher's electrical circuits.