30
Installation Guide ____________
; Water Connection MD-1000LT
MD-1000LT • Water Connection
(3/4" NPT line strainer not supplied)
Water supply: 3/4" NPT hot water supply (140°F/60°C minimum)
(35 psi/241 KPa static pressure) 7-10 psi/48-69Kpa flow pressure
Note:
Under NO circumstances, may the installing plumber connect a water supply line to the
dishwasher that is less than 3/4" NPT in size.
Note:
The following components are not required for proper dishwasher operation, but are
highly recommended, because they make servicing of the dishwasher much faster.
Install the following components (not supplied) in the hot water supply line:
1) 3/4” or larger water shut-off valve near the machine in the water supply line.
2) ASSE 1010 Water hammer arrestor upstream from the shut-off valve.
3) Pressure gauge 0-60 PSI minimum downstream from the PRV.
4) Temperature gauge 0-180°F/82°C (not supplied) downstream from the gauge.
Note:
Plumbing installer must connect a 3/4" NPT hot water supply line to the dishwasher.
A 3/4" pressure regulating valve (PRV) (not supplied) must be installed in the water
supply line and adjusted to (35 psi/241 KPa static pressure) 7-10 psi/48-69Kpa flow pressure