10
1. Unlock the top-mounted control cabinet with the key. two keys should be stowed behind the
control cabinet. The installing electrician used one key during their installlation.
2. Locate the cycle timer mounted in the right-rear corner of the control cabinet.
3. Refer to the MD-1000HT electrical schematic located at the end of this manual.
Installation Guide _____________
; Chemical Dispensers MD-1000HT
115VAC Power Connections for Chemical Dispensers
FOR QUALIFIED INSTALLERS ONLY
Continued from page 9
Caution:
Connecting chemical dispensers at points other than those recommended by the factory may
damage the dishwasher electrical system.
Damage caused by the installation of chemical equipment will not be covered by our WARRANTY.
Warning:
Disconnect the main electric supply and place a tag at the fuse or
disconnect switch indicating that work is being performed on that circuit.
Warning:
Chemical dispensers must be electrically grounded in compliance with applicable electric codes.