Sharp R-1900J Toaster User Manual


 
14
NOTES:
1. Only Dual Digit Input method can be used when inputting
memory numbers in Multiplication Factors for Double/
Triple Quantity.
2. The multiplication factors can be set from 0.01 to 9.99 for
double quantity and triple quantity.
3. When you want to know the multiplication factor for triple
quantity, press the DOUBLE/TRIPLE QUANTITY twice at
step 1 after pressing the CUSTOM SETTING pad twice.
4. Multiplication Factors for Double/Triple Quantity can be
checked or changed before pressing the STOP/CLEAR pad
to exit for Custom Setting function.
11. Express Defrost Setting
Express Defrosting uses 3 stages to defrost foods quickly.
The defrosting sequence is preset as follows, but you can
change the setting.
Defrosting Time Power Level
STAGE
1
T x A1: (0.20*) + B1: (20*) sec. PL1 (40*) %
STAGE
2
T x A2: (0.13*) + B2: (30*) sec. PL2 (30*) %
STAGE
3
T - STAGE1 - STAGE2 PL3 (20*) %
Pause
Timing
See the table for The Pause
Timing below (50*)
T : INPUT TIME (TOTAL COOKING TIME)
* : The numbers in the parentheses are factory settings
and can be adjusted.
Express Defrost is preset to pause during the sequence
when 50% of total defrosting time has passed to check food.
Pause timings can also be adjusted.
Pause Timing
KEY
Display
Pause Timing
0 0 No pause.
1 1 After 10% of total cooking time.
2 2 After 20% of total cooking time.
3 3 After 30% of total cooking time.
4 4 After 40% of total cooking time.
5 5 After 50% of total cooking time.
6 6 After 60% of total cooking time.
7 7 After 70% of total cooking time.
8 8 After 80% of total cooking time.
9 9 After 90% of total cooking time.
START A After ending of each stage
2 Press the MANUAL/
REPEAT pad and enter
desired multiplication for
A1 at Stage 1.
(Ex: Enter 3,0 for 0.30.)
4 Press the POWER LEVEL
pad and enter desired
power level for PL1 at
Stage 1.
(Ex: Enter 5 for 50%)
* Suppose you want to change the Express Defrost set
factory settings to the following:
Defrosting Time Power Level
STAGE 1 T x 0.30 + 10 sec. 50%
STAGE 2 T x 0.15 + 20 sec. 20%
STAGE 3 T - STAGE1 - STAGE2 10%
Pause
Timing
When 70% of total defrosting time has
passed.
Procedure Display
1 Press the CUSTOM
SETTING pad twice
within 2 seconds and
press the EXPRESS
DEFROST pad.
(The Express Defrost
setting of each phase is
shown for 1.5 seconds
at 0.3 second intervals
until the MANUAL/
REPEAT pad is pressed.)
x2
1
DEF.
DEF.
DEF.
3
0
DEF.
5
DEF.
DEF.
DEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
CHECKDEF.
(STAGE 1)
(A1)
(B1)
(Power Level 1)
(STAGE 2)
(A2)
(B2)
(Power Level 2)
(STAGE 3)
(Pause Timing)
(Power Level 3)
3 Press the MANUAL/REPEAT
pad and enter desired time
for B1 at Stage 1.
(Ex: Enter 1 for 10 seconds.)
R-1900J [EN].indd Sec1:14R-1900J [EN].indd Sec1:14 4/28/09 10:01:27 AM4/28/09 10:01:27 AM