Instructions for the installer
4. FINAL OP TIONS
After replacing the nozzles, reposition the flame-spreader crowns, the
burner caps and the grids.
ERA
Following adjustment to a gas other than the preset one, replace the gas
adjustment label fixed to the appliance with the one corresponding to the
new gas. This label is in the packet together wit . h the nozzles
4.1 Adjustment of minimum for natural gas
Light the burner and turn it to the minimu
position
m
. Extract the gas tap knob and turn the
adjustment screw at the side of the tap rod un
the correct minimum flame is achieved.
Replace the knob and check burner fl m
stability: (rapidly turning the knob from maximum
to minimum position, the flame should not go
out). Repeat the operation on all the gas taps.
til
a e
4.2 Mounting the rear top upstand
• Position the upstand above the top, taking care to align holes A with
holes B.
• Secure the upstand to the top by tightening screws C.
14