Smeg A3SX Cooktop User Manual


 
Instructions for the installer
2. INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by authorised persons.
Clearance around the cooker must comply with the requirements of
AS5601.
2.1 Positioning and levelling of the appliance
This appliance is fitted with 4 castors for easy positioning. To block the
appliance in tis final position, extract the feet on the front and screw the
corresponding castors in.
CAUTION: delicate floors could be damaged by the castors; in this case,
lift the appliance with a mechanical means.
2.2 Electrical connection
Make sure that the power line voltage matches the specifications
indicated on the rating plate located inside the storage compartment.
This rating plate must never be removed.
The connection to the mains shall be done conforming to the regulations
in force. Check that the power line is adequately grounded. Do not use
reducers, adapters or shunts. On the power line, install an omnipolar cut-
off device with contact cut-off distance greater than or equal to 3 mm,
located in an easily accessible position near the unit.
For operation on 400-415V3N
: use
an H05RR-F-type five-core cable (5 x
1.5 mm
2
).
For operation on 400-415V2N
: use
an H05RR-F-type four-core cable (4 x
2.5 mm
2
).
For operation on 230-240V
: use an
H05RR-F-type three-core cable (3 x 4
mm
2
).
The cable end to be connected to the
appliance must be provided with an
ground wire (yellow-
g
reen) at least 20
mm longer.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
6