Model 428Operating Procedures
140718
Step 5
Place the mix hopper cover in position. For proper
operation, there must be a substantial amount of mix
in the hopper. If the ADD MIX light illuminates, refill the
mix hopper as soon as possible.
Figure 44
Closing Procedure
To disassemble this unit, the following items will be
needed:
S T wo cleaning pails
S Necessary brushes (provided with freezer)
S Cleaner
S Single s ervice towels
Draining Product From The
Freezing Cylinder
Step 1
Place the power switch in the OFF position as far
ahead of cleaning time as possible to allow frozen
product to s often for easier cleaning.
Step 2
Remove the hopper cover and the air/mix feed tube (if
the unit is equipped with an air/mix feed tube). Take
these parts to the s ink for c leaning.
Step 3
If local health codes permit the use of rerun,place
a sanitized, NSF approved stainless steel rerun
container beneath the door spout. Place the power
switch in the W ASH position and move the draw
handle to the right. When product stops flowing from
the door spout, move the draw handle to the left and
place the power switch in the OFF position. Place the
sanitized lid on the r erun container and place it in the
walk- in cooler.
Note: If local health codes DO NOT permit the use
of rerun, the product must be discarded. Drain the
product into a pail and properly dis card it.
ALWAYS FOLLOW LOCAL HEALTH CODES