Taylor 8751 Freezer User Manual


 
24
Models 8751/8754Operating Procedures
Step 2
Once a steady stream of mix starts to flow from the
prime plug opening in the bottom of the freezer door,
push down the pr ime plug.
Figure 41
Step 3
When the mix stops bubbling down into the freezing
cylinder, insert the mix feed tube. Remove t he locking
clip from the outlet fitting of the mix pump. Insert the
outlet end of the mix feed tube int o the mix inlet hole
in the mix hopper. Place the inlet end of the mix feed
tube into the outlet fitting of the mix pump. Secure with
locking clip.
Figure 42
Step 4
Press the AUTO key. When the unit cycles off, the
product will be at serving viscosity.
Figure 43
Step 5
Fill the hopper with fresh mix. As the mix level comes
in contact with the mix l evel sensing probe on the front
wall of the hopper, t he MIX LOW light will shut off.
Note: The MIX REF light will come on, indicating the
mix refrigeration system is maintaining mix in the mix
hopper.
Step 6
Place the mix hopper cover in pos ition.
Repeat steps 1 through 6 for the other side of the
freezer on the M odel 8754.
Closing Procedure
To disassemble your unit, the following items will be
needed:
S T wo cleaning pails
S Sanitized s tainless steel rerun can with lid
S Necessary brushes (provided with freezer)
S Cleaner
S Single service towels