6
Models 150, 152, 162, 168Safety
130722
S DO NOT allow untrained personnel to operate
this unit.
S DO NOT put objects or fingers in door spout.
S DO NOT operate the freezer unless all service
panels and access doors are restrained with
screws.
S DO NOT remove the freezer door or beater
assembly unless the control switches are in
the “OFF” position.
Failure to follow these instructions may result in severe
personal injury from hazardous m oving parts.
This unit has many sharp edges that can
cause severe injuries.
S DO NOT put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
S USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades are
very sharp.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
Access to the service area of the unit is
restricted to persons having k nowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
Cleaning and sanitizing schedules are
governed by your state or local r egulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to c lean this unit.
This unit is designed to maintain product
temperature under 41_F(5_C). Any product being
added to this unit must be below 41_F(5_C). Failure
to follow this instruction may result in health hazards
and poor freezer per formance.
DO NOT obs truct air intake and discharge openings:
S 150 and 152: Minimum of 6” (152 mm) of
clearance around both sides. Install the skirt
provided on the right side of the unit and place
the back of the unit against a wall to prevent
recirculation of warm air .
S 162: Minimum of 6” (152 mm) on all sides.
Install the skirt provided on the rear of the unit.
S 168: Minimum of 3” (76 mm) on all sides.
Install the skirt provided on the rear of the unit.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70_-75_F(21_-24_C). The unit has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
DO NOT run the unit without product. Failure to follow
this instruction c an result in damage to the unit.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the unit and at a height of 1.6
meters from the floor.