Models 150, 152, 162, 168 Important: To the Operator
Cylinder Temperature Retention
(CTR)
To maintain a good quality product during long “ No
Sale” periods, it will be necessary to warm the product
in the freezing cylinder to approximately 35_ to 40_F
(1.7_ to 4.4_C). This will prevent overbeating and
product breakdown. The CTR is used in conjunction
with the S HR to insure that the mix in the freezing
cylinder is refrigerated during the “STANDBY” mode of
operation.
To operate t he “STANDBY” m ode of operation:
Place the power switch in the “AUTO” position and the
mix refrigeration switch in the “STANDBY” position.
With sanitized hands, remove the feed tube. Turn it
over and place the end without the hole into the mix
inlet hole.
To resume normal operation:
Leave the power switch in the “AUTO” position and
place the mix refrigeration switch in the “AUTO”
position. When the unit cycles off, the product in the
freezing cylinder will be the correct viscosity. With
sanitized hands, remove the feed tube. T urn it over
and place the end with the hole into the mix inlet hole.