Traulsen 789 Ice Maker User Manual


 
-36-
VIII. CONTROL PARAMETERS
VIII. d - R-SERIES PARAMETER SETTINGS (MIT II Control Version):
Control Refrigerator Models
Parameter RA1 RA2 RA3 RA4 RA5 RA6 RA7 RA8
ADR 2 2222222
BAU 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6
NAF ON ON ON ON ON ON ON ON
SPH 39.2 39.2 39.2 39.2 38.1 38.1 39.2 39.2
SPL 37 37 37 37 34 34 37 37
SHL 39.2 39.2 39.2 39.2 36 36 39.2 39.2
SHH 40 40 40 40 40 40 40 40
SLL 34 34 34 34 32 32 34 34
SLH 37 37 37 37 34 34 37 37
RO 0 0000000
HI 41 41 41 41 41 41 41 41
LO 30.2 30.2 30.2 30.2 30.2 30.2 30.2 30.2
SCL F FFFFFFF
HAD 15 15 15 15 15 15 15 15
LAD 2 2222222
AC 3 3333333
DEF OFF OFF OFF OFF OFF OFF ELE ELE
IBD 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0
DDC 10 10 10 10 10 10 20 20
CDE 45.1 45.1 45.1 45.1 45.1 45.1 70 70
DDE 2 2222222
BDD 0 0000000
BSD 32 32 32 32 32 32 32 32
ODD 10 10 10 10 10 10 10 10
SD
Starts a new defrost cycle at any time or stops a current defrost cycle.
CFA OFF ON OFF ON ON ON OFF ON
CCR 20 20 20 20 20 20 20 20
CDL 220.1 220.1 220.1 220.1 220.1 220.1 220.1 220.1
DOA ON ON ON ON ON ON ON ON
DAD 15 15 15 15 15 15 15 15
APD 2 2222222
ATD 10 10 101010101010
AAS OFF OFF OFF OFF OFF OFF OFF OFF
CL Set the hours and minutes in military time.
DAY Set the year, month, day of the month and day of the week.
DS ON ON ON ON ON ON ON ON
DL1 OFF OFF OFF OFF OFF OFF OFF OFF
DL2 OFF OFF OFF OFF OFF OFF OFF OFF
DL3 OFF OFF OFF OFF OFF OFF OFF OFF
DL4 OFF OFF OFF OFF OFF OFF OFF OFF
DCF 100 100 100 100 100 100 100 100
CON 11 11 11 11 11 11 11 11
COF 10 10 10 10 10 10 10 10
EL
Will display evaporator coil temp in real time every time an arrow is pressed.
DL
Will display discharge line temp in real time every time an arrow is pressed.
CB
Will display cabinet air temp in real time every time an arrow is pressed.
PLn*
Will display power line voltage in real time every time an arrow is pressed.
RCO*
Turns ON/OFF the compressor relay for 10-seconds or until an arrow is pressed.
RdF*
Turns ON/OFF the defrost relay for 10-seconds or until an arrow is pressed.
RFA*
Turns ON/OFF the blower relay for 10-seconds or until an arrow is pressed.
RDH*
Turns ON/OFF the door heater triac for 10-seconds or until an arrow is pressed.
PRO* Set the controller in receiving mode for programming.
CEP* Clear all controller memories and reloads the factory default parameters.
REF*
Firmware revision in the format X9.9 (X=version, 9=major revision, 9=minor revision).
*MIT II control version only.