Vulcan Materials VC4GS Oven User Manual


 
FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 (Rev. B, October 2007) Page 18 of 68
COOLING FAN
1. Remove the right side panel as outlined under
COVERS AND PANELS.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2. Disconnect the lead wires to the fan motor by
removing wire nuts.
3. Remove the screws securing the air deflector to
the fan then loosen the tab screw holding the
fan to the component panel. Rotate the tab so
that the fan will clear and remove the fan.
4. Reverse the procedure to install the
replacement fan and check for proper operation.
NOTE: The fan must be installed so air is pulled from
the rear of the oven and blown into the control area.
The arrow on the fan body indicates AIR FLOW
direction and should be pointing toward the controls.
NOTE: Ensure fan is seated SQUARELY against the
air tube and the oven bottom.
NOTE: The air deflector should be angled upwards
at approximately 30 degrees to properly direct the air
flow.