FULL SIZE GAS CONVECTION OVENS - CONDENSED SPARE PARTS LIST
CODE & PROBLEM PROBABLE CAUSE SOLUTION
F24682 (Rev. B, October 2007) Printed in U.S.A.
Er06 - Zone 1 A/D underflow
error
• Incorrect sensor type
• Measuring temperature outside the
sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor. If the
condition causing the error is
resolved, the error will clear.
Er07 - Zone 1 A/D overflow
error
Open sensor • Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor. If the
condition causing the error is
resolved, the error will clear.
Er10 - Stack overflow error Microprocessor malfunction • Cycle power.
• Check sensor and connections for a
reversed or open sensor.
Er11 - Open sensor error Open sensor • Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor.
Er12 - Shorted sensor • Incorrect sensor type
• Measuring temperature outside the
sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor.