FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 (Rev. B, October 2007) Page 8 of 68
TEMPERATURE PROBE
(VC4GD/6GD)
1. Remove the right side panel as outlined under
COVERS AND PANELS.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2. Disconnect the probe leads from the
temperature control.
3. Remove the racks and right rack support.
4. Remove probe clips from probe.
5. Push the probe through the opening in cavity
side wall and into the control panel area.
NOTE: The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
6. Reverse the procedure to install the
replacement probe.
7. Adjust the temperature control as outlined under
SOLID STATE TEMPERATURE CONTROL
CALIBRATION (VC4GD/6GD) in SERVICE
PROCEDURES AND ADJUSTMENTS.
GAS BURNER
Shut off the gas before servicing
the unit.
1. Remove the lower front cover as outlined under
COVERS AND PANELS.
2. Disconnect the ignition cable and the flame
sense lead wire.
3. Remove the bolts securing the gas manifold
and place manifold aside.
4. Remove the screws securing the burner cover
then lift out.
5. Grasp the burner and lift out.